Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Fire Protection Engineering
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1042391509104183v1
19/3/197    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Dong, Y.
Right arrow Articles by Prasad, K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Behavior of Full-scale Frames with Slim Floor Slab Construction under Exposure in a Fire Resistance Furnace

Yuli Dong

School of Civil Engineering, Harbin Institute of Technology, China, dongyl{at}hit.edu.cn

Kuldeep Prasad

National Institute of Standards and Technology Gaithersburg, MD, USA

In recent years, there has been increasing interest in developing and designing slim floor systems in steel-framed buildings. This article describes the results of a furnace test conducted on two full-scale composite steel frames with slim floor slab construction to understand their performance under fire loading. In one frame, the beam-to-column connections were protected, while in the second frame, the columns as well as the beam-to-column connections were protected. During the test, the furnace temperature, the steel and concrete temperature, as well as the horizontal and vertical displacements were recorded. The complete deformation process of the test frame observed during the heating phase and the cooling phase, including failure of the frame, is described in this article. A comparison of the data obtained from the two tests indicates that the fire resistance of a composite beam is significantly better than that of a steel column. Fire resistance of composite frames with slim floor slabs is compared with data on a conventional floor slab. Results indicate that the fire resistance rating of frames constructed with slim floor slabs is at least as good as that of frames with conventional floor slab construction.

Key Words: slim floor • structural failure • furnace heating • composite steel frame • fire resistance.

This version was published on August 1, 2009

Journal of Fire Protection Engineering, Vol. 19, No. 3, 197-220 (2009)
DOI: 10.1177/1042391509104183


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?